My OPV Is Leaking/Water Is Running Out of It

If the OPV is leaking on your Profitec Pro 600 or water is running from it, you may have a blockage or need to clean the solenoid. Read below on how to diagnose and resolve the issue.

 

  • If the machine is fully heated and still leaking consistently or water is just pouring out of it. Lift the brew lever up and down and listen for a โ€œclickโ€ from the intake solenoid. If the solenoid is clicking, removal and cleaning of the intake solenoid is necessary. Definitely do this if the water dripping out becomes steam, and steam is pouring out of the drain.
  • With no portafilter in place, lift lever. If no flow out of the group head is present and water is flowing from the Drain, remove the top of the group head and inspect the jet for a blockage.
  • If water is just running through out of the discharge and the pump is constantly running. A blockage maybe be present on the intake line into the boiler, this Can be removed and inspected, or the machine will need to be sent in for repair/hydraulic system descaling.
  • The Pro 600 has a line that goes from the top of the vacuum breaker into a plastic T-connector that attaches to the front discharge of the machine. If steam is pouring out of the discharge, it is likely due to a sticking vacuum breaker that will not seal so it is constantly venting steam out of the discharge. The vacuum breaker should be taken apart and cleaned/lubricated. If this does not work then it should be replaced.

 

 