Learn what to do if your Gaggia Accademia is showing a "No Flow" error but you are still getting flow, and how to troubleshoot the flow meter.
Have Flow But Getting No Flow Error
In some situations, you will be able to get flow through the machine for all functions, but the machine thinks there is no water flowing through. There is a device in the machine called a flow meter, and it tells the machine when water is flowing through or not. The device operates by having small fan-like blades spin when water passes through it. If those blades get stuck from excessive scale buildup or debris, then they will not spin. As a result, even though water is flowing through the machine, you will get a flow error.
If your machine uses a water filter, temporarily remove it from the water tank and add the Gaggia Decalcifier to the water tank. The descaler needs to work its way into the system to start dissolving the scale buildup in the flow meter. You may have to keep restarting the machine so that it can keep attempting to prime, which will draw the descaler/water solution into the system. If at any point you are able to clear the flow message then you will want to do an immediate descale of the machine. After you have descaled, run 4-5 tanks of plain water through the hot water function for the wand in order to ensure the system is completely free of debris.
Associated Parts:
Failure of normal wear and tear items such as group gaskets, seals, and shower screens are not covered under warranty. Issues due to scale build-up or lack of maintenance are not covered.
If you would like to have one of our skilled technicians repair your machine, click the link
below.