๐Ÿ“น How to Resolve No Water Coming Out When the Water Valve is Open on the Profitec Pro 600

There Is No Water Coming Out when I Open the Water Valve

If there is no water flowing from the hot water valve on your Profitec Pro 600 when you open it, it may be blocked. Read on to diagnose your machineโ€™s water flow issues and how to resolve them.

First, make sure that the steam valve works, and the issue has been isolated to just the hot water side of the machine.               

                         

Is it showing approx 1.2 bars of pressure?

  • Yes.
    • Remove the hot water tip. Open the hot water wand. Does water come out?
      • Yes. Remove the tip from the hot water tap and test the flow. If flow is restored then the tip needs to be cleaned and reattached. Mineral deposits can easily collect in the screen/holes of the hot water tap, so be sure to clean these thoroughly. Soaking the tip in a solution of hot water and backflushing powder will help remove residues more effectively.
      • No. There may be a blockage in the wand of the hot water tap. Clean the wand by using a pipe brush that has synthetic or plastic bristles; metal bristles can damage the wand. Then soak the wand in a solution of hot water and dish soap. Backflushing powders should not be used due to the chemicals, which can cause a reaction that will strip or change certain metals different colors, especially if any type of coating is missing
      • No. Allow machine to cool, remove the housing, remove the copper pipe off the back of the hot water valve and check for a blockage if no blockage is present in the valve or the end of the pipe, a blockage is present on the boiler side. Should be sent in for repair/descale of hydraulic system.

 

 