My OPV is leaking/ water is running out of it

The OPV is the little elbow pipe on the front of the machine, below the E61 group on your Expobar Brewtus IV. If it is leaking, refer to the instructions below on how to correct the issue.

If the machine is fully heated and still leaking consistently or water is just pouring out of it. Lift the brew lever up and down and listen for a “click” from the intake solenoid. If the solenoid is clicking, Give our experts a call and we can advise you further.
With no portafilter in place, lift lever. If no flow out of the group head is present and water is flowing from the Drain, remove the top of the group head and inspect the jet for a blockage.
If water is just running through out of the discharge and the pump is constantly running. A blockage maybe be present on the intake line into the boiler. This can be removed and inspected, or the machine will need to be sent in for Repair/ hydraulic system descale.